Electricians in Alford

We are electricians working in Alford and the villages around it, Bilsby, Willoughby and Huttoft among them. A lot of homes here are off the gas grid, some are thatched and many sit at the end of a long supply, and each of those changes the electrical work.

Electric heating off the gas grid

Where there is no gas, many homes heat with electricity, often old storage heaters on an off peak meter. Most electric room heaters sold since 2018 have had to meet the ecodesign rules, which in practice means electronic thermostats, timers and controls that respond to the room. Swapping a set of old storage heaters is therefore a chance to get far better control of the heat as well as replacing worn kit.

Each heater wants the right circuit, and an off peak meter wants its circuits clearly separated and labelled at the board. Getting that right is what lets the cheaper overnight units do their job, and it is notifiable work that we certify and register.

Wiring for heat pumps fitted by others

We do not install heat pumps, but we wire them for the specialist installers who do. That means a supply from the board sized for the unit, an isolator beside it and the controls connected inside.

A heat pump also has to be notified to the network operator, and on a rural supply that is worth checking early. A house at the end of a long line, with a small main fuse and perhaps a car charger planned too, may need the supply looked at before the heat pump can run as designed.

Thatched cottages and the electrics inside them

Alford has thatched buildings, its manor house among them, and so do some of the villages around it. Thatch changes the rules on wiring. Fire and rescue service guidance on thatched homes, Suffolk's among them, asks for wiring connections, aerial leads and supply cables to be kept at least 30cm clear of the thatch and its wire netting. Cables in a roof space under thatch belong in conduit, with no joints hidden in the thatch and no recessed downlights in a ceiling below it, because of the heat they give off.

Some thatch insurers ask for a regular electrical inspection, and an EICR is the way to show it. On a cottage where the wiring has been added to over decades, an inspection usually comes before any other work.

Long supplies to barns, workshops and garages

Village properties often have outbuildings a long way from the house. A cable that long loses voltage along its length, and the wiring regulations set limits on how much, so the cable size is worked out from the distance and the load, not guessed. Armoured cable, a small board in the outbuilding and the right earthing arrangement at the far end are what make it safe.

A new supply to an outbuilding is a new circuit and so notifiable, and we certify and register it like any other.